Skip to main content

NGS Multiplex Oligos for Illumina (Index Primers Set I) (C007B-484606)

Catalog No.
C007B-484606
Manufacturer No.
N665658-96T
Manufacturer Name
Aladdin Scientific
Quantity
1
Unit of Measure
ST

Product content:Component:N665658-24T:N665658-96T:Adaptor for Illumina:60 μl:240 μl:Universal Primer for Illumina:30 μl:120 μl:Index 1–12 Primers for Illumina:12×10 μl:12×20 μl:Product Introduction:This kit provides the adaptor and primer used in

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account. Contact Us

Product content:Component:N665658-24T:N665658-96T:Adaptor for Illumina:60 μl:240 μl:Universal Primer for Illumina:30 μl:120 μl:Index 1–12 Primers for Illumina:12×10 μl:12×20 μl:Product Introduction:This kit provides the adaptor and primer used in second-generation sequencing library construction, designed for illumina platform library construction, index primer design can meet the needs of multiple high-throughput sequencing to prepare multiple library samples, the prepared library can be used for Illumina GAIIx, HiSacnSQ, HiSeq 2500/ 2000/1000 and MiSeq sequencing sequencing platform sequencing. 2000/1000 and MiSeq sequencing.Provide your own instruments, reagents and consumables:1. Magnetic frame: DynaMagTM-2 is recommended.2. DNA purification recovery kit.3. DNA building kit.4. Anhydrous ethanol.5. Reaction tubes: It is recommended to use low adsorption PCR tubes with 1.5 ml centrifuge tubes;:6. Tip: It is recommended to use a high quality filter tip to prevent contamination of kits and library samples.Pre-experiment Preparation and Important Notes:1. Adaptor is a double chain structure, do not leave it above room temperature to avoid unraveling and affecting the use.2. Please centrifuge the Index primer briefly before uncapping so that the liquid collects at the bottom of the tube to avoid cross-contamination between different primers.Usage process:Operation steps:Please follow the protocol of the second-generation sequencing rapid DNA library building kit for the use of the second-generation sequencing multi sample connector primer kit.Adaptor for Illumina:5´-/5Phos/ GATCGGAAGAGCACACGTCTGAACTCCAGT*C -3´:5´-ACACTCTTTCCCTACACGACGCTCTTCCGATC*T-3´:Universal Primer for Illumina:5-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATC*T -3´:Index 1–12 Primers for Illumina:Index Primers for Illumina:Index:Index 1 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATCGTGAT:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :ATCACGAT:Index 2 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATACATCG:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :CGATGTAT:Index 3 Primer:for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATGCCTAA:GTGA:CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :TTAGGCAT:Index 4 Primer:for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATTGGTCA:GTGA:CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :TGACCAAT:Index 5 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATCACTGT:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :ACAGTGAT:Index 6 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATATTGGC:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :GCCAATAT:Index 7 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATGATCTG:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :CAGATCAT:Index 8 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATTCAAGT:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :ACTTGAAT:Index 9 Primer:for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATCTGATC:GTGA:CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :GATCAGAT:Index 10 Primer:for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATAAGCTA:GTGA:CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :TAGCTTAT:Index 11 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATGTAGCC:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :GGCTACAT:Index 12 Primer for Illumina:5-CAAGCAGAAGACGGCATACGAG:ATTACAAG:GTGA CTGGAGTTCAGACGTGTGCTCTTCCGATC-s-T-3´: :CTTGTAAT.

Specifications and Purity: for Illumina

UPC:
10161604
Condition:
New
HazmatClass:
No
WeightUOM:
LB
MPN:
N665658-96T
Product Size:
96T

Cenmed Satisfaction Guarantee
Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.

Testimonial
"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR

Testimonial
"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER

Testimonial
"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN

Testimonial
"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.