General description
This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com
Methiocarb sulfone is a carbamate pesticide and one of the four metabolites of insecticide, molluscicide, and bird-repellent methiocarb.
As per the commission implementing regulation (EU) 2019/1606 of 27th September 2019, methiocarb (expressed as the sum of methiocarb, methiocarb sulfone, and methiocarb sulfoxide) is not approved for use in the European Union. Maximum residue levels (MRLs) have been set according to Reg (EC) No 149/2008 for methiocarb (expressed as the sum of methiocarb, methiocarb sulfone, and methiocarb sulfoxide) for various products of plant and animal origin from 0.01 to 0.1 mg/kg. Methiocarb has to be monitored in the Multiannual Control Program for Pesticides Residues (MACP), run within the EU and EFTA in/on products of plant origin.
Application
The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
The methiocarb sulfone CRM may also find following uses:
- Method development for simultaneous determination of methiocarb, methiocarb sulfoxide, and methiocarb sulfone in five food products of animal origin (milk, chicken, pork, beef, and eggs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Determination of 304 pesticide residues in citrus fruit (grapefruit, lemon, orange and mandarin) and vegetable (cucumber, eggplant, tomato and zucchini) samples by liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
- Analysis of environmental water samples for the presence of 23 carbamate pesticide residues by solid-phase extraction (SPE) combined with ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
- Develop a UHPLC-MS/MS method to determine 28 carbamate pesticide residues in fresh herb samples of basil, spearmint, wild mint, parsley, Chinese parsley, thyme, chives, and salvia after their QuEChERS-based extraction
- Validation of a method based on QuEChERS extraction and LC-MS/MS and GC-MS/MS quantification of 218 pesticide residues in clay loam soil
- Multi-residue analysis of pesticides and mycotoxins in red wine using direct injection for sample preparation and UPLC-MS/MS for analysis
- Method development for detection and quantification of 260 pesticides and mycotoxins in green tea and royal jelly nutraceutical products by “dilute and shoot†extraction procedure and quantification by LC-Orbitrap-MS
Legal Information
TraceCERT is a registered trademark of Sigma-Aldrich Co. LLC
Molecular Weight: 257.31. Empirical Formula: C11H15NO4S. grade: certified reference material, TraceCERT®. . Quality Level: 300. product line: TraceCERT®. . shelf life: limited shelf life, expiry date on the label. manufacturer/tradename: Manufactured by: Sigma-Aldrich Production GmbH, Switzerland. storage temp.: 2-8°C. SMILES string: CNC(: O)Oc1cc(C)c(c(C)c1)S(C)(: O): O. InChI: 1S/C11H15NO4S/c1-7-5-9(16-11(13)12-3)6-8(2)10(7)17(4,14)15/h5-6H,1-4H3,(H,12,13). InChI key: RJBJMKAMQIOAML-UHFFFAOYSA-N. Pictograms: GHS07. Signal Word: Warning. Hazard Statements: H302. Precautionary Statements: P264 - P270 - P301 + P312 - P501. Hazard Classifications: Acute Tox. 4 Oral. Storage Class Code: 11 - Combustible Solids. WGK: WGK 3. Flash Point(F): Not applicable. Flash Point(C): Not applicable.- UPC:
- 12162004
- Condition:
- New
- HazmatClass:
- No
- MPN:
- CRM67124-100MG
- CAS:
- 2179-25-1
- Temperature Control Device:
- Yes
akash.verma@cenmed.com