O-10-100/3022Reversed-Phase C8 Column: Particle Size: 10 m, Pore Size: 100 Angstrom, Length: 300mm, I. D.: 22.1mm
O Series SMT SAM-C8 phase with the highest functional ligand coverage confirmed with carbon analysis results of 12% carbon load. In these series, a very high density of the functional ligand, octyl molecule or C8, is achieved through meticulous -
OD-5-100/2522Reversed-Phase C18 Column: Particle Size: 5 m, Pore Size: 100 Angstrom, Length: 250mm, I. D.: 22.1mm
OD Series: SMT SAM-C18 phase with the highest functional ligand coverage confirmed with carbon analysis results of 24% carbon load. In these series, a very high density of the functional ligand, octadecyl (C18) molecule, is achieved through -
O-10-100/2522Reversed-Phase C8 Column: Particle Size: 10 m, Pore Size: 100 Angstrom, Length: 250mm, I. D.: 22.1mm
O Series SMT SAM-C8 phase with the highest functional ligand coverage confirmed with carbon analysis results of 12% carbon load. In these series, a very high density of the functional ligand, octyl molecule or C8, is achieved through meticulous -
OD-10-300/2522OD Series: SMT SAM-C18 phase with the highest functional ligand coverage confirmed with carbon analysis results of 24% carbon load. In these series, a very high density of the functional ligand, octadecyl (C18) molecule, is achieved through -
O-10-100/1522Reversed-Phase C8 Column: Particle Size: 10 m, Pore Size: 100 Angstrom, Length: 150mm, I. D.: 22.1mm
O Series SMT SAM-C8 phase with the highest functional ligand coverage confirmed with carbon analysis results of 12% carbon load. In these series, a very high density of the functional ligand, octyl molecule or C8, is achieved through meticulous -
O-5-300/3010O Series SMT SAM-C8 phase with the highest functional ligand coverage confirmed with carbon analysis results of 12% carbon load. In these series, a very high density of the functional ligand, octyl molecule or C8, is achieved through meticulous -
O-5-100/3010O Series SMT SAM-C8 phase with the highest functional ligand coverage confirmed with carbon analysis results of 12% carbon load. In these series, a very high density of the functional ligand, octyl molecule or C8, is achieved through meticulous -
O-10-100/3010O Series SMT SAM-C8 phase with the highest functional ligand coverage confirmed with carbon analysis results of 12% carbon load. In these series, a very high density of the functional ligand, octyl molecule or C8, is achieved through meticulous -
O-5-100/308O Series SMT SAM-C8 phase with the highest functional ligand coverage confirmed with carbon analysis results of 12% carbon load. In these series, a very high density of the functional ligand, octyl molecule or C8, is achieved through meticulous