Weak carboxylic acid modified polymeric cation exchanger for SPE Features Base material spherical PS/DVB copolymer, pore size 50&ndash60 Å, particle sizes 45 µm or 85 µm (standard), very large specific surface 850 m2/g, pore
Weak carboxylic acid modified polymeric cation exchanger for SPE Features Base material spherical PS/DVB copolymer, pore size 50&ndash60 Å, particle sizes 45 µm or 85 µm (standard), very large specific surface 850 m2/g, pore
Dimethyl modified silica phase for SPE, not endcapped Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2&ndash8 Dimethyl phase, not endcapped, carbon content 4 % Similar to C4
Dimethyl modified silica phase for SPE, not endcapped Features Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m2/g, pH stability 2&ndash8 Dimethyl phase, not endcapped, carbon content 4 % Similar to C4
polar phase Crossbond polyethylene glycol Restek&rsquos polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding
polar phase Crossbond polyethylene glycol Restek&rsquos polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding
proprietary Crossbond diphenyl/dimethyl polysiloxane phase Rtx-Volatiles columns were the first columns designed specifically for analyses of the 34 volatile organic pollutants listed in U.S.
proprietary Crossbond diphenyl/dimethyl polysiloxane phase Rtx-Volatiles columns were the first columns designed specifically for analyses of the 34 volatile organic pollutants listed in U.S.
Redesigned to be more rugged and easier to use! Match your needs with three levels of protection: filter only, cartridge only, or filter and cartridge Durable metal tip with replaceable PEEK ferrule means easy installation onto column without tools
Redesigned to be more rugged and easier to use! Match your needs with three levels of protection: filter only, cartridge only, or filter and cartridge Durable metal tip with replaceable PEEK ferrule means easy installation onto column without tools
NUCLEOCEL DELTA Cellulose-modified silica phases for HPLC enantiomer separation Features Base material silica with chiral selector cellulose tris-(3,5-dimethylphenylcarbamate) USP L40 S versions with 5 &mum particle size for higher resolution,
NUCLEOCEL DELTA Cellulose-modified silica phases for HPLC enantiomer separation Features Base material silica with chiral selector cellulose tris-(3,5-dimethylphenylcarbamate) USP L40 S versions with 5 &mum particle size for higher resolution,