-
726360.3OPTIMA® 5 Amine GC capillary columns for amine separation Features Especially deactivated for the analysis of polyfunctional amines such as ethanol­amines, amino-functionalized diols and similar compounds, which are important base materials -
726630.3OPTIMA® 1701 MS Capillary columns for GC Features Silarylene phase with selectivity analog to 14 % cyanopropyl-phenyl &ndash 86 % dimethylpolysiloxane USP G46 Mid-polar phase with very low bleed 100 % ion trap and quadrupol MS compatibility -
726154.3OPTIMA® 35 MS capillary columns for GC Features Silarylene phase with selectivity analogue to 35 % phenyl &ndash 65 % methylpolysiloxane USP G42 / close equivalent to USP G28 / G32 Medium polar phase with very low bleeding Recommended for ion -
726821.3OPTIMA 1 capillary columns for GC, film thickness: 0.35 m, length: 30 m, 0.32mm ID, USP: G1, G2, G38
OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns &ge 3 µm film are expecially recommended for solvent -
726323.3OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns &ge 3 µm film are expecially recommended for solvent -
723830.25PERMABOND® FFAP Capillary columns for GC Features Polyethylene glycol 2-nitroterephthalate close equivalent to USP G25 / G35 Polar phase Recommended for FAMEs, free carboxylic acids Similar phases: OPTIMA® FFAP, DB-FFAP, HP-FFAP, CP-Sil 58 -
726807.3OPTIMA® 5 Capillary columns for GC Features 5 % phenyl &ndash 95 % methylpolysiloxane · USP G27, G36 Nonpolar standard phase with large range of application Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed -
726600.3OPTIMA® WAX Capillary columns for GC Features Polyethylene glycol 20 000 Da USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax -
726065.25OPTIMA® 17 Capillary columns for GC Features Phenylmethylpolysiloxane (50 % phenyl) · USP G3 Medium polar phase Recommended application: steroids, pesticides, drug analyses Low bleed columns with equal selectivity see OPTIMA® 17 MS -
726066.25OPTIMA® 17 Capillary columns for GC Features Phenylmethylpolysiloxane (50 % phenyl) · USP G3 Medium polar phase Recommended application: steroids, pesticides, drug analyses Low bleed columns with equal selectivity see OPTIMA® 17 MS -
726220.15OPTIMA 5 MS capillary columns for GC, film thickness: 0.25 m, length: 15 m, 0.25mm ID, USP: G27, G36
OPTIMA® 5 MS Capillary columns for GC Features 5 % diphenyl &ndash 95 % dimethylpolysiloxane USP G27 / G36 Nonpolar phase with low bleeding Suited for GC/MS and ECD application and general analyses at trace level Perfect inertness for basic -
akash.verma@cenmed.com
(732) 447-1115



