726787.6OPTIMA® 624 Capillary columns for GC Features 6 % cyanopropyl-phenyl &ndash 94 % dimethylpolysiloxane USP G43 Medium polar phase Recommended for environmental analyses For corresponding columns with lower film thickness see OPTIMA® 1301 -
723321.5Capillary columns for GC Features Polyethylene glycol 20 000 Da · USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: OPTIMA® WAX, DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, -
726050.6OPTIMA 1 capillary columns for GC, film thickness: 0.25 m, length: 60 m, 0.25mm ID, USP: G1, G2, G38
OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns &ge 3 µm film are expecially recommended for solvent -
726860.5OPTIMA® 5 Capillary columns for GC Features 5 % phenyl &ndash 95 % methylpolysiloxane · USP G27, G36 Nonpolar standard phase with large range of application Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed -
726118.5OPTIMA® 225 Capillary columns for GC Features 50 % cyanopropylmethyl &ndash 50 % phenylmethylpolysiloxane · USP G7 / G19 Medium polar phase Recommended for fatty acid analyses Similar phases: DB-225, HP-225, OV-225, Rtx-225, CP-Sil 43, -
726050.5OPTIMA 1 capillary columns for GC, film thickness: 0.25 m, length: 50 m, 0.25mm ID, USP: G1, G2, G38
OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns &ge 3 µm film are expecially recommended for solvent -
726442.3OPTIMA® &delta-3 Capillary columns for GC Features Polysiloxane phase with autoselectivity USP G49 Medium polar without CN groups Analytes determine the polarity of the phase Autoselectivity resulting in a polarity range from approximately the -
723555.25PERMABOND FFAP capillary columns for GC, film thickness: 1 m, length: 25 m, 0.53mm ID, USP: G35, G25
PERMABOND® FFAP Capillary columns for GC Features Polyethylene glycol 2-nitroterephthalate close equivalent to USP G25 / G35 Polar phase Recommended for FAMEs, free carboxylic acids Similar phases: OPTIMA® FFAP, DB-FFAP, HP-FFAP, CP-Sil 58 -
723549.25Capillary columns for GC Features Polyethylene glycol 20 000 Da · USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: OPTIMA® WAX, DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, -
726202.3OPTIMA® 1 MS Capillary columns for GC Features 100 % dimethylpolysiloxane USP G1 / G2 / G38 Nonpolar phase with low bleeding Suited for GC/MS and ECD application and general analyses at trace level Similar phases: Ultra-1, DB-1MS, HP-1MS, -
726523.3OPTIMA® 5 Capillary columns for GC Features 5 % phenyl &ndash 95 % methylpolysiloxane · USP G27, G36 Nonpolar standard phase with large range of application Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed -
726529.25OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns &ge 3 µm film are expecially recommended for solvent