-
9903395Note: 0.25-0.32mm inner diameter. columnsrequire 0.5mm inner diameter ferrules. 0.53mm inner diametercolumns require 0.8mm inner diameter ferrules. -
725802.6OPTIMA® 1 MS Accent Ultra-low bleed capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase with ultra-low bleeding, ideal for ion trap and quadrupole MS detectors Increased sensitivity due to an -
725805.6OPTIMA® 1 MS Accent Ultra-low bleed capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase with ultra-low bleeding, ideal for ion trap and quadrupole MS detectors Increased sensitivity due to an -
726400.5OPTIMA® &delta-3 Capillary columns for GC Features Polysiloxane phase with autoselectivity USP G49 Medium polar without CN groups Analytes determine the polarity of the phase Autoselectivity resulting in a polarity range from approximately the -
726400.25OPTIMA® &delta-3 Capillary columns for GC Features Polysiloxane phase with autoselectivity USP G49 Medium polar without CN groups Analytes determine the polarity of the phase Autoselectivity resulting in a polarity range from approximately the -
726225.6OPTIMA® 5 MS Capillary columns for GC Features 5 % diphenyl &ndash 95 % dimethylpolysiloxane USP G27 / G36 Nonpolar phase with low bleeding Suited for GC/MS and ECD application and general analyses at trace level Perfect inertness for basic -
726304.6OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns &ge 3 µm film are expecially recommended for solvent -
726302.6OPTIMA 1 capillary columns for GC, film thickness: 0.25 m, length: 60 m, 0.32mm ID, USP: G1, G2, G38
OPTIMA® 1 Capillary columns for GC Features 100 % dimethylpolysiloxane · USP G1 / G2 / G38 Nonpolar phase Separation of components according to boiling points Thick film columns &ge 3 µm film are expecially recommended for solvent -
726162.6OPTIMA® 17 MS Capillary columns for GC Features Silarylene phase with selectivity analogue to 50 % phenyl &ndash 50 % methylpolysiloxane USP G3 Medium polar phase with very low bleeding Ideal for ion trap detectors, optimum reference column in -
723296.6PERMABOND CW 20 M capillary columns for GC, film thickness: 0.5 m, length: 60 m, 0.32mm ID, USP: G16
Capillary columns for GC Features Polyethylene glycol 20 000 Da · USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: OPTIMA® WAX, DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, -
726809.5OPTIMA® 5 Capillary columns for GC Features 5 % phenyl &ndash 95 % methylpolysiloxane · USP G27, G36 Nonpolar standard phase with large range of application Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed -
723827.5Capillary columns for GC Features Polyethylene glycol 20 000 Da · USP G16 Polar phase Recommended for solvent analysis and alcohols, suitable for aqueous solutions Similar phases: OPTIMA® WAX, DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX,
akash.verma@cenmed.com
(732) 447-1115



